Piezoelectric High Pressure Transducers GP Series
Piezoelectric high pressure transducers based on GaPO4 technology
|
- High accuracy
- High reliability
- High sensitivity
- Wide measuring range
- Small dimensions
|
|
|
|
|
Compared with Quartz Gallium Phosphate has significant advantages:
- Thermal stability up to 970 °C
- Excellent stability of piezolectric constant over a wide pressure range
- Twice the sensitivity of tourmaline and quartz
- No pyroelectricity
- Stable material due to industrial process
|
Specifications and Behaviour
|
|
GP 2 |
GP 6 |
GP 8 |
|
Pressure range, MPa |
200 |
600 |
800 |
 |
Overload, MPa |
240 |
640 |
840 |
Sensitivity (nom), pC/MPa |
55 |
30 |
25 |
Linearity, % |
≤ ± 0.5 |
Operating temperature, °C |
- 50 ... 200 |
Temperature coefficient, %/°C |
- 0.01 |
Insulation resistance at 20 °C, Ohm |
≥ 1013 |
Natural frequency, kHz |
≥ 240 |
Rise time µs |
≤ 1 |
Acceleration sensitivity axial, MPa/g radial, MPa/g |
0.0002 0.0005 |
< 0.0002 < 0.0005 |
0.0002 0.0005 |
Shock resistance axial, MPa/g radial, MPa/g |
25000 10000 |
Mounting thread, mm |
M10 x 1 |
Mounting torque, Nm |
20 |
Weight, g |
12 |
Cable connector |
Microdot 10-32 UNF |
|
← For detailed product information, please click "More Information" in the left menue bar
(if the "RFI" Form is already opened, bring it to the foreground).
|